O’ Keefe Orthodontal, Waterford

O’ Keefe Orthodontal, Waterford

O’ Keefe Orthodontal, Waterford - Specialist Glazed Screens and Doors Project overview p Name O’ Keefe Orthodontal  Address Waterford Project Details Specialist Glazed Screens and Doors Crofton Interiors was commissioned by O’ Keefe Orthodontal, Waterford to deliver...
Abbott, Cootehill

Abbott, Cootehill

Abbott Cootehill Cleanroom Wraparound Fire Glazing Project overview p Name Abbott  Address Cootehill, Co. Cavan  Contractor Meegan Builders Ltd Project Details Stainless Steel EI60 Fire-Rated Flush Dual-Glazed Acoustic Rated Cleanroom Screens Crofton Interiors was...
Belvedere College

Belvedere College

Belvedere College Project overview p Name Belvedere College  Address Dublin  Contractor Clancy Construction Project Details Scope of Works: Specialist Fire Glazing Private School Fire Glazing on escape routes and stairwells over 6 floors. Works consist of: Schüco...
Beckett Locke

Beckett Locke

Beckett Locke Project overview p Name Beckett Locke  Address Beckett Locke, Dublin  Architects Avroko Architects  Contractor Bennett Construction Ltd Project Details Glazed Moveable Wall, Slimline Steel Glazed Doors and Screens Crofton Interiors was commissioned to...
Fyffes HQ

Fyffes HQ

Fyffes HQ Project overview p Name Fyffes HQ  Address M1 Business Park, Courtlough, Balbriggan, Co. Dublin  Architects Scott Talon Walker Architects  Contractor Meegan Builders Ltd Project Details Crofton Interiors was commissioned to deliver the requirements for...
ESB Finglas

ESB Finglas

ESB, Finglas Project overview p Name ESB Finglas  Address St. Margarets Road, Finglas, Dublin  Contractor Structuretone Ltd Project Details Timber Doors, Glazed Screens with Fire Rated Glazed Atrium Crofton Interiors was commissioned to deliver specialist glazing...

Ireland

In order for Crofton Interiors to help you in the most effective and efficient way possible, your enquiry should have a specification which includes:

The Fire resistance Eurocode Classification. For Doors and Screens separately e.g. E 30, EI 30, E 60, EI 60, EI 1201
Glass Joints Butt Jointed Glass-to-Glass joints or Fully Framed Glass panes Door Functionality Latched on Lever handles/ Unlatched Non rebated on Push/Pull Handles/ Panic Function (EN 179 or EN1125).2
Paint Specification Standard RAL or Metallic RALAcoustic requirements
Steel Type Mild steel or Stainless Access Control Requirements Maglock / Electric Lock / Electric Strikes
Floor Plan Drawings Elevation Drawingsshowing the layout of the glazed screens and doors
Bill of Quantities or Schedule

1 Non-Eurocode fire classifications for Glazing Systems (e.g. ambiguous descriptions such as “FD30”, “30/30”, “30 minutes” “FR30”) are a thing of the past and are the single biggest factor causing serious regulatory and cost increase issues across the industry from enquiry stage to Practical completion. Getting this right is half the battle.

2 If this is not known, please let us know the building tenancy arrangements (single/multiple), floor occupancy factor, perceived frequency of use of the door.

Some notes for your consideration:

  • The Acoustic Ratings offered by all Glazed Office Partitioning Contractors are dB Rw which means that the stated dB Rw acoustic rating (weighted sound reduction index for the human ear) of the system is the rating achieved under laboratory test conditions in accordance with EN ISO 717: 2013 (still current as at March 2020). It is not possible or advisable for a Glazing subcontractor to prove or offer a site tested result (dB R’w) due to various site specific factors, the most relevant one being flanking sound transmission through the structures that the glazed partition is affixed to.
  • Expect a site test result to always be less than the result of laboratory test conditions.
  • Most doors will have a lesser acoustic rating than the screens they are installed into.