GLAZED AND FIRE RATED SCREENS

Crofton Interiors along with our market leading partners, can offer the widest range of partitioning systems that may include special acoustic partitions, fire rated screens and acoustic doors.
We have carefully selected functional and flexible systems, enabling our partitions to be adopted to suit all types of buildings. Specialist Areas include:

  • Single Glazed Systems
  • Double Glazed Systems
  • Fire Rated Glazed Screens and Doors
  • Frameless and Framed Doors and Sliding Doors
  • Selection of different finishes and bespoke manifestations

Our Glazed Partition products are constantly developing ensuring we remain the market leaders when it comes to performance and design. Please contact a member of our team to learn more on our products and how we can meet your needs.

PRODUCT FEATURES & SPECIFICATIONS

Single Glazed

Single Glazed Partitions

Areas formed with fully glazed partitions create a light, spacious and attractive environment in large or small rooms and in either new or existing buildings.

System Thickness: 25mm
Dry Joined: Glass to glass and glass to aluminium
Acoustics: 12mm Toughened 35dB
12.8mm Stadip silence 38dB
Door Options: Frameless or aluminium framed 12mm toughened
Veneered door in an aluminium or timber frame
Flush bonded glazed door in a frame
Framed or frameless sliding glass door
Finishes: Satin anodised
Simulated satin stainless steel finished
Powder coated (any RAL or BS colour)
Manifestation: Applied film (Opal Frost, Dusted Crystal etc)
Digital printed graphics on optically clear film
Drywall Abutments: Fully integrated double glazed drywall endcaps

Double Glazed

Double Glazed Partition

A Frameless Double Glazed Partition from Crofton Interiors is the perfect solution when effective sound reduction is required while maintaining a light and elegant interior.

System Thickness: 50mm
Dry Joined: Glass to glass and glass to aluminium
Acoustics: 2 x 12mm Toughened 40dB
2 x 12.8mm Stadip silence 45dB
Door Options: Frameless or aluminium framed 12mm toughened
Veneered door in an aluminium or timber frame
Flush bonded glazed door in a frame
Framed or frameless sliding glass door
Finishes: Satin anodised
Simulated satin stainless steel finished
Powder coated (any RAL or BS colour)
Manifestation: Applied film (Opal Frost, Dusted Crystal etc)
Digital printed graphics on optically clear film
Drywall Abutments: Fully integrated double glazed drywall endcaps suitable for 100mm and 122mm drylined walls

Fire Rated

Fire Rated Glazed Partitions

Crofton Interiors offer a large selection of Fire Rated Systems which can be seamlessly integrated with our standard Glazed Partitions forming a uniformed continuous appearance in your building.

Our Fire Rated Partitions are available in several different fire classifications depending on your requirements and can be incorporated into existing or new solid walls.

  • Single Glazed Fire Partition: Partition thickness ranges from 35mm to 44mm and using Glass thickness from 20mm to 31mm
  • Double Glazed Fire Partition: Partition thickness ranges from 92mm to 230mm and using Glass thickness from 12mm to 24mm (2 layers)

Fire Rated Doors

To complement our Fire Rated Partitions, our Fire Door products can be produced with an attractive aluminium frame and with either solid or glazed doors. Alternatively, a Fire Rated Timber Door and Frame can be easily integrated into the system to produce the desired results. All options are fire and sound rated.

Case Studies: Republic of Ireland

DEUTSCHE BANK DUBLIN HQ

GENERALI INSURANCE

SLIGO IT – LIBRARY EXTENSION

Case Studies: Northern Ireland

MURRAY TOBACCO WORKS

Like What You See?

Ireland

In order for Crofton Interiors to help you in the most effective and efficient way possible, your enquiry should have a specification which includes:

The Fire resistance Eurocode Classification. For Doors and Screens separately e.g. E 30, EI 30, E 60, EI 60, EI 1201
Glass Joints Butt Jointed Glass-to-Glass joints or Fully Framed Glass panes Door Functionality Latched on Lever handles/ Unlatched Non rebated on Push/Pull Handles/ Panic Function (EN 179 or EN1125).2
Paint Specification Standard RAL or Metallic RALAcoustic requirements
Steel Type Mild steel or Stainless Access Control Requirements Maglock / Electric Lock / Electric Strikes
Floor Plan Drawings Elevation Drawingsshowing the layout of the glazed screens and doors
Bill of Quantities or Schedule

1 Non-Eurocode fire classifications for Glazing Systems (e.g. ambiguous descriptions such as “FD30”, “30/30”, “30 minutes” “FR30”) are a thing of the past and are the single biggest factor causing serious regulatory and cost increase issues across the industry from enquiry stage to Practical completion. Getting this right is half the battle.

2 If this is not known, please let us know the building tenancy arrangements (single/multiple), floor occupancy factor, perceived frequency of use of the door.

Some notes for your consideration:

  • The Acoustic Ratings offered by all Glazed Office Partitioning Contractors are dB Rw which means that the stated dB Rw acoustic rating (weighted sound reduction index for the human ear) of the system is the rating achieved under laboratory test conditions in accordance with EN ISO 717: 2013 (still current as at March 2020). It is not possible or advisable for a Glazing subcontractor to prove or offer a site tested result (dB R’w) due to various site specific factors, the most relevant one being flanking sound transmission through the structures that the glazed partition is affixed to.
  • Expect a site test result to always be less than the result of laboratory test conditions.
  • Most doors will have a lesser acoustic rating than the screens they are installed into.